WDG-3A – कंट्रोल सर्किट (GFC CONTROL CIRCUIT )

January 4, 2021, 12:08 AM
Share

GFC CONTROL CIRCUIT 
To move the loco, field of Traction Alternator is to be excited by exciter generator. This work is done with the help of GFC contactor. It is electro magnetic contactor. To pickup this contactor GFC coil circuit is designed. This circuit starts from wire no. 13. When both control stand GFCO kept in close and MH closed (MH 1 – 8), the supply of wire no. 13 goes to wire no. 6 via wire no. 30E, 30C, and 30CC. Supply of wire no. 6 goes to GFC coil through following normally close interlocks
BKT (M)                 NCI                               6-6A 
ECS(R)                   NCI                               6A-6B 
GFOLR                  NCI                                6B-6C 
GR1                       NCI                                6C-6D 
BKT (M)               NCI                                6D-6E 
TR                         NCI                                6E-6F 
CK3                      NCI                                6F-6H 
GF coil will energize by wire 6H positive and wire 4 negative and GFC contactor pick up. 
Other than this following interlocks are provided parallel to BKT (M) & TR (NCI). 
NOI of P32 (6D-6F), NOI of P2 (6D-6F) will close at the time of parallel transition. 
MCO NOI (6D-6F) will close at the time of TM isolation.
   
Disclaimer: Disclaimer: The Information, News, Videos, Articles, and other content provided on this platform have been collected, compiled, or referenced from various sources available in the public domain. We believe that “Knowledge Is Power” and our aim is to create general awareness among people and make useful information easily accessible to everyone. While we make reasonable efforts to present information accurately and responsibly, we do not guarantee that all information, news, videos, or other content published on this platform is complete, current, or free from errors. Users are advised to independently verify important information from official or authoritative sources before relying upon it or taking any action based on it. NOTE: The content on this platform is intended for general information and awareness purposes only and should not be considered as professional, legal, financial, medical, or official advice. Knowledge Hub Information Center does not assume responsibility for any loss, damage, or consequence arising from reliance on information published on this platform.